Beckman Bottle Insert set of 6 new-in-box

PDFPrintEmail
Beckman bottles for JLA 10.500 rotor, set of 6 new carbon fiber bottles p/n 362750
2015_06_25_Beckman_362750_JLA10.500_012
2015_06_25_Beckman_362750_JLA10.500_038
2015_06_25_Beckman_362750_JLA10.500_05
2015_06_25_Beckman_362750_JLA10.500_04
Description

SOLD!

Beckman 362750 new in box, set of 6 carbon fiber bottle inserts for use with JLA 10.500 rotor.

Specifications - 

Maximum speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 000 rpm
Critical speed range*. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600 to 800 rpm
Maximum solution density . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 g/mL
Relative Centrifugal Field†
at maximum speed
at rmax (166 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 600 × g
at rav (110 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 300 × g
at rmin (54 mm) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 050 × g
k factor at maximum speed (full 500-mL bottle) . . . . . . . . . . . . . . . . 2 850
Conditions requiring speed reduction . . . . . . . . . . . . . . see SPEED LIMITS
Number of removable cannisters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Nominal dimensions of largest bottle . . . . . . . . . . . . . . . . . . . 69 × 160 mm
Nominal bottle capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 mL
Nominal rotor capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 liters
Weight of fully loaded rotor (with lid) . . . . . . . . . . . . . . . 16.2 kg (35.7 lb)
Minimum installation weight (rotor body
and windshield) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8.9 kg (19.7 1b)
Weight of single empty cannister . . . . . . . . . . . . . . . . . . . . 240 g (0.53 1b)
Maximum sample load for each cannister at rated speed
(including labware and sample; not including
closure, if applicable). . . . . . . . . . . . . . . . . . . . . . . . . . 665 g (1.47 lb)
Approximate acceleration time to maximum speed
(rotor fully loaded) in an Avanti J-25 centrifuge . . . . . . . . . . 2 1
/2 min
Approximate deceleration time from maximum speed
(rotor fully loaded, max. brake) in an
Avanti J-25 centrifuge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 min
Maximum allowable imbalance of opposing loads. . . . . . . . . . . . . . . . 10 g
Rotor body material. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . aluminum
Cannister material . . . . . . . . . . . . . . . . . . . . . carbon fiber epoxy composite
Rotor entry code for Avanti J-E and microprocessor-controlled
J2 series centrifuges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.5