Beckman Coulter C0650, new-in-box
SOLD!
Beckman Coulter C0650 Fixed-Angle Rotor, 10,000rpm, new-in-box -
For Use in the Beckman Coulter Allegra 64R, Avanti 30, Allegra X-22 Series, Allegra 21 Series, GS-15 Series, Spinchron 15 Series, and Allegra X-30 Series Centrifuges.
Specifications -
Maximum speed:
Allegra 64R/Avanti 30/Allegra X-30R . . . . . . . . . . . . . . . . . . . . . .10,000 rpm
Allegra X-22R/Allegra 21R/GS-15R/Spinchron 15R . . . . . . . . . . . ..9,500 rpm
Allegra X-22/Allegra 21/GS-15/Spinchron 15/Allegra X-30. . . ...... ..9,000 rpm
Density rating at maximum speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 g/mL
Critical speed rangea . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 to 700 rpm
Relative Centrifugal Fieldbat maximum speed at rmax (92.0 mm):
Allegra 64R/Avanti 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10,400 g
Allegra X-30R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10,304 g
Allegra X-22R/ Allegra 21R/GS-15R/Spinchron 15R . . . . . . . . . . . . 9,420 g
Allegra X-22/Allegra 21/GS-15/Spinchron 15 . . . . . . . . . . . . . . . . . 8,420 g
Allegra X-30 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8,346 g
Run Speeds Number of tube cavities . . . . . . . . . . . . . . . . . . . .. . . . 6
Nominal tube dimensions . . . . . . . . . . . . . . . . . . . . . . . . 28.5 107 mm (conical)
Nominal tube capacity (largest tube) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mL
Nominal rotor capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 mL
Approximate acceleration time to maximum speed (fully loaded). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 min
Approximate deceleration time from maximum speed (fully loaded). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 min
Weight of fully loaded rotor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 kg (11.5 lb)
Rotor and lid material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . aluminum
a. The critical speed range is the range of speeds over which the rotor shifts so as to rotate about its center of mass. Passing through or running at the critical speed range is characterized by some vibration. b. Relative Centrifugal Field (RCF) is the ratio of the centrifugal acceleration at a specified radius and speed (r2) to the standard acceleration of gravity (g) according to the following formula: RCF = r/g — where r is the radius in millimeters, is the angular velocity in radians per second (2 RPM /60), and g is the standard acceleration of gravity (9807 mm/s2). After substitution: RCF = 1.12r (RPM/1000).